In-situ functionalization of aniline oligomer onto layered graphene sheet and study of its application on electrochemical detection of ascorbic acidin food samples
https://doi.org/10.17586/2220-8054-2016-7-4-774-779
Abstract
Aniline oligomers are considered as one of the electron transfer mediators for the electrochemical oxidation of ascorbic acid. The electrochemical oxidation of ascorbic acid was investigated using aniline oligomer-functionalized polymer modified electrode. In the present investigation, we demonstrated a novel methodology for the in-situ modification of aniline oligomer onto the layered graphene sheet by using diazonium salt form as precursor molecule. An enhanced electrocatalytic current was obtained for the oxidation of ascorbic acid using aniline pentamer-functionalized reduced graphene oxide (AP-rGO). Detailed studies have been carried out to study the surface modified rGO by FTIR spectroscopy. A linear relationship between peak current against the concentration of ascorbic acid was observed within the ranges from 1 µM to 10 µM. The detection limit was measured at signal/noise (S/N) of 3. The present method can be utilized for the electrochemical detection of ascorbic acid present in food products like fruit juices.
About the Authors
S. DevasenaIndia
Department of Chemistry
Madurai–625009
S. Meenakshi
India
Department of Inorganic Chemistry
Guindy, Chennai–600025
R. Sayeekannan
India
Department of Chemistry
Madurai–625009
K. Pandian
India
Department of Inorganic Chemistry
Guindy, Chennai–600025
References
1. DeNobili M.D., Perez C.D., Navarro D.A., Stortz C.A., Rojas A.M. Hydrolytic stability of L-(+)-ascorbic acid in low methoxyl pectin films with potential antioxidant activity at food interfaces. Food Bioprocess Technol., 2011, 6, P. 186–197.
2. Jens L. Determination of ascorbic acid and dehydroascorbic acid in biological samples by high performance liquid chromatography using subtraction methods: Reliable reduction with tris (2-carboxyethyl) phosphine hydrochloride. Anal. Biochem., 2000, 282, P. 89–93.
3. Yu Y.H., Donat P.H. UV-B-induced formation of reactive oxygen species and oxidative damage of the cyanobacterium Anabaena sp.: protective effects of ascorbic acid and N-acetyl-L-cysteine. J. Photochem. Photobio. B: Biology, 2002, 66, P. 115–124.
4. Wu T., Guan Y., Ye J. Determination of flavonoids and ascorbic acid in grapefruit peel and juice by capillary electrophoresis with electrochemical detection. Food Chem., 2007, 100, P. 1573–1579.
5. Ping J., Wang Y., Wu J., Ying Y., Ji F. Determination of ascorbic acid levels in food samples by using an ionic liquid carbon nanotube composite electrode. Food Chem., 2012, 135, P. 362–367.
6. Francis F.J. Wiley encyclopedia of food science and technology, 2-nd ed., Vol 4. Wiley, New York, 1999.
7. Habibi B., Pournaghi-Azar M.H. Simultaneous determination of ascorbic acid, dopamine and uric acid by use of a MWCNT modified carbon-ceramic electrode and differential pulse voltammetry. Electrochimica Acta, 2012, 55, P. 5492–5498.
8. Roy P.R., Saha M.S., Okajima T., Ohsaka T. Electrooxidation and amperometric detection of ascorbic acid at GC electrode modified by electropolymerization of N, N-Dimethylaniline. Electroanalysis, 2004, 16, P. 289–297.
9. Florou A.B., Prodromidis M.I., Stella M.T.K., Miltiades I. Fabrication and voltammetric study of lanthanum 2,6-dichlorophenolindophenol chemically modified screen printed eletrodes: Application for the determination of ascorbic acid. Anal. Chimica Acta, 2000, 423, P. 107– 114.
10. Zuo X., Zhang H., Li N. An electrochemical biosensor for determination of ascorbic acid by cobalt (II) phthalocyanine- multiwalled carbon nanotubes modified glassy carbon electrode. Sensors Actuat., 2012, 161, P. 1074–1079.
11. Hummers W.S., Offemn R.E. Preparation of graphitic oxide. J. Am. Chem. Soc., 1958, 80, P. 1339.
12. Huang L., Hu J., Lang L., Wang X., Zhang P., Jing X., Wang X., Chen X., Lelkes P.I., MacDiarmid A.G., Wei Y. Synthesis and characterization of electroactive and biodegradable ABA block copolymer of polylactide and aniline pentamer. Biomaterials, 2007, 28, P. 1741–1751.
Review
For citations:
Devasena S., Meenakshi S., Sayeekannan R., Pandian K. In-situ functionalization of aniline oligomer onto layered graphene sheet and study of its application on electrochemical detection of ascorbic acidin food samples. Nanosystems: Physics, Chemistry, Mathematics. 2016;7(4):774-779. https://doi.org/10.17586/2220-8054-2016-7-4-774-779